| .pdf version | |||||||||||||||||||||||||||||||||||||||||||
| NSI-901V-3x3 | |||||||||||||||||||||||||||||||||||||||||||
Model
901V-3x3 Sub-mm Wave (550 GHz)
![]() |
|||||||||||||||||||||||||||||||||||||||||||
| DESCRIPTION
Model 901V-3x3 is ideal for measuring satellite antennas at sub-millimeter wave frequencies. The figure shows the planar test system that was delivered to test NASA's Sub-millimeter Wave Astronomy Satellite (SWAS). The mission of this satellite is to measure the emissions from intergalactic gas clouds at frequencies of 540-560 GHz. The NSI system provided extremely high planarity and thermal stability, necessary for tests at this high frequency. |
|||||||||||||||||||||||||||||||||||||||||||
| CAPABILITIES
The system includes special thermal
compensation techniques to minimize the
phase change in the measurement RF cables,
AUT, and scanner. NSI was awarded a patent
(U.S. Patent No. 5,419,631) for this work.
This patented technology is incorporated in
to our Motion Tracking Interferometer (MTI)
product. |
|||||||||||||||||||||||||||||||||||||||||||
FEATURES
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
| DIMENSIONS
|
|||||||||||||||||||||||||||||||||||||||||||
LINKS
|
|||||||||||||||||||||||||||||||||||||||||||
| ORDERING
INFORMATION 2.8' x 2.8' (0.86 m x 0.86 m) granite measurement system including X-Y stepper motor driven scanner, 40' motor cable set, controller, PC based measurement workstation, motor drive electronics, NSI Antenna Measurement Software, X-band probe kit with probe absorber and mounting bracket, installation tool kit, system documentation and operation manual. |
|||||||||||||||||||||||||||||||||||||||||||
| Nearfield
Systems, Incorporated 19730 Magellan Drive, Torrance, CA 90502, USA, Tel: 310.525.7000, Fax: 310.525.7100 Email: sales@nearfield.com. Visit our website: www.nearfield.com |
|||||||||||||||||||||||||||||||||||||||||||