Antenna Measurement Systems |
| |
| .pdf
version |
| |
| |
NSI-RF-TRU |
| Transmit/Receive
Unit (TRU)

|
| DESCRIPTION
The
NSI-RF-TRU Transmit/Receive Unit (TRU) features improved integration
for range automation. Like the RTM,
the TRU allows automation of configuration changes while simplifying
system operation. The TRU allows the range operator to switch configurations
without changing RF cable connections, thereby reducing errors and
improving productivity.
The NSI-RF-TRU
is available in various configurations depending
upon automation requirements. The TRU provides a wide range of options
and modules for automating any type of antenna range. TRU modules
combine high quality RF components and switches to provide a flexible
platform for a wide variety of antenna range configuration control.
TRU
modules incorporate switchable amplifiers, couplers,
mixers, programmable step attenuators and other RF elements that
may be combined in a variety of ways to create a highly automated
antenna range. TRU modules are more highly integrated than RTM modules and are capable of being mounted on the probe carriage for some scanners.
|
| FEATURES
- Modular
design supports high level of range automation requirements
- 1
to 18.0 GHz (Higher frequency modules available upon request)
- LNA
and programmable step attenuator integrated
with mixer module
- Compatible
with NSI Panther or Agilent PNA systems
- Modules
include base, mixer,
2nd LO mixer, 40/50 GHz Multiplier.
|
- Mixer
modules are identical and connect to DFC LO/IF unit with
single LO/IF cable
- Test
and reference LO cables do not have to be of the same length
- Remote
operation through standard LAN interface
- TRU
Dynamic Link Library is compatible with NSI2000 script language
and can support stand alone applications
- Includes
easy-to-use TRUPanel software
|
TRU SYSTEM BLOCK DIAGRAM

NSI-RF-TRU Used
to Automate Near-field Range Configuration (LO/IF cables not shown)
TRU BLOCK DIAGRAM (Base Module & Two
Mixers)

|
| INCLUDES THE FOLLOWING
COMPONENTS |
TRUPanel
Software provides easy-to-use interface for TRU configuration
and status monitoring
|
NSI-RF-TRU
Transmit/Receive Unit
TRUPanel
software
DLL
for integration with other applications
Power
supply & cord
User
Guide and Programming Manual
Two
year warranty
Modules Available:
Base
(amplifier, coupler, RF Switches, control)
Mixer
(LNA, PSA, DFC Mixer, RF Switches)
2nd
LO (RF Switches, Mixer)
40 GHz TRU Multiplier module
50 GHz TRU Multiplier module
|
|
| OPERATION The
NSI-RF-TRU communicates with a host computer
using a LAN interface. The message-based protocol and object-oriented
software provide a modular, easy-to-use environment for antenna range
automation.
The TRUPanel
application provides a virtual front panel for the user to configure
and monitor status of the TRU. Multiple TRUs in a system are easily
controlled by the TRUPanel software. The NSITRU.DLL software allows
custom automation solutions to be developed for a wide range of platforms
including NSI 2000 Scripts, VB and VBA. |
SPECIFICATIONS
|
Frequency Range |
1 to 18.0 GHz (1 to 40 or 50 GHz for Mpy modules) |
|
Base Module Amplifier Gain |
24 dB |
|
Base Module Amplifier Pout |
+17 dBm |
| Mixer
LNA Gain |
34
dB |
| Mixer
LNA Pout |
+8
dBm |
| Mixer
LNA NF |
3
dB |
| Minimum
Mixer LO Power |
-20
dBm |
| Mixer
Programmable Step Attenuator |
0
to 81 dB, steps of 1 dB |
| Mixer
Conversion Efficiency |
>
10 dB |
| Mixer
Compression |
>
-24 dBm |
| Mixer
Sensitivity (PNA, IF BW=1000) |
<
-110 dBm |
| Mixer
Isolation, Ref to Test Channel |
>
100 dB |
| RF
Switch Isolation |
90
dB |
| RF
Switching Time |
15
ms |
| RF
Switch Cycles |
5
million |
| TRU
Response Time (typ) |
40
ms |
|
RF Connectors |
SMA female (2.9 or 2.4 for Mpy modules) |
Module Size (HxWxD) |
10" x 1.5" x 12.0" |
| Module
Weight |
~15
lbs |
TRU
Size (3 module unit, HxWxD) |
7 " x
19" x 15.0" |
| TRU
Weight (3 module unit) |
~30
lbs |
| TRU
Power (24V power adapter included) |
4.2
A @ 24 VDC |
|
Controls and Indicators |
DC power and error LED on each module |
|
| |
ORDERING INFORMATION
Contact
the NSI Sales Department to configure a TRU system to meet your
automation needs.
Nearfield
Systems, Incorporated
19730 Magellan Drive, Torrance,
CA 90502, USA, Tel: 310.525.7000, Fax: 310.525.7102
Email: sales@nearfield.com. Visit our website: www.nearfield.com
|